About US Contact US Electronic Products Picture Gallery Home Site Map
   
 
 
Solar water heater
Solar Sinewave Inv
Solar cell
Solar Street Light
Solar power Supply
Solar Hand Light
Solar UPS
Heater working Digr.
FPC heater picture
Step-up transformer
ETC heater picture
Offline UPS
Home Inverter
Mobile mortuary
Deep Freezers
Online  UPS
Servo voltage stabilizer
Stabilizer
110 volt Transformer
Ups cum inverter
Air-conditioner
Automotive Inverter
Tubular Battery
Water Cooler
Sine wave Inverter
SolarInverter+UPS

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Murickens
Mobile Mortuary
Solar Inverter
Deep Freezer
Servo Stabilizer
Solar Devise
UPS
Kerala Properties
Solar water Boiler
Kerala Real Estate  
Renewable energy
Voltage Stabilizer
Kerala Realtor
Stepup Transformer
Air Conditioner 
Cochin Property
Sine wave UPS
Kottayam Land
Kerala house-land
Electronic Generator
Solar lights
No.1 web portal
powerbackupdevise
Solar waterheater
 
  
 
 

MG SOLAR WATER HEATER

Murickens has developed a water heater using solar energy.  The heat from the sun is used to heat the water by a special method (FPC) so that hot water is available 24 hours, even in rainy days. Since this instrument is fixed on top of the building where sun light can strike the panel, additional space inside the house is not required.  There is no electric hazard and no electricity bill to be paid.  Pay only the initial installation charge and enjoy the natural hot water 24 hours.  Suitable for houses, hospitals, hotels and factories.  We have different capacity of Solar Water Heaters to suit ones pocket.

 

We have two models solar water heaters Viz:-1. Flat plate collector (FPC) – An  insulated, weather-proofed box containing a dark absorber plate under one or more transparent or translucent covers. This is the most common type solar water heater. Murickens has tested and proved since 30 years  that it is the most suitable type for Kerala's climatic conditions and get 80°C hot water with the help of only normal sunlight. We have Pressurized MG solar water heater and Non -pressure solar water heater in FPC model.
 
Second one is Evacuated Tube Collectors (ETC) which is made up of rows of parallel, transparent glass tubes. Each tube consists of a glass outer tube and an inner tube called absorber which is covered with a selective coating. The demerits of ETC models are, we get only very low temperature, i.e.  heat up 40 ± 5°C.   Water leakage through glass sealing, chance of brakeage of tubes when it is exposed to sunlight, chance to catch fungus inside the tube and consequently lower the heat of water. On rainy season, must have  use electrical heater.

 

Murickens Kerala solar water heating device contains the solar collector panels, the working fluid (water) and the storage tank. Special black or dark green coatings are used to absorb the energy. The heat absorbed by collector panels with size of 2 meter length and 1 meter width with 9 fins is used to heat water in normal capacities. When solar collectors are exposed to sun light, the water flowing through tubes in the panels is heated. Copper tubes transfer the collected heat to the water more effectively than aluminum, steel or glass tubes. The covering over the collector reduces the escape of collected heat to the outside air. The cover is transparent to short-wave solar radiation, but not to infrared radiation from the selective surface. The back and side insulation, typically R-value 12, reduces conduction losses. Heated water from solar panel collects in a storage tank which is specially designed to preserve the heat for a longtime.

 

MG SOLAR WATER HEATER FEATURES:
  Maintenance free. Water heated up to 80°C. No electrical hazard. No expenses after installation. The best way of getting natural hot water for cooking and industrial purpose  Copper capillaries.   P U F system and glass wool to avoid conduction loss for storage tank.   Light weight. T I G welded fins and tubes. Compact in size.   Heat expulsion. Fully automatic. High quality tempered 4mm thick front glass.    Sturdy and weather proof design.    Different Capacity starting from 125 liters to 1000 liters.   Custom built Solar Water Heater can also be provided. Two models FPC and ETC. In FPC special model we can connect pressure pump.

MG SOLAR FPC WATER HEATER TECHNICAL SPECIFICATION:

MG solar water  heater FPC model 125 150 250 500
Usage No. of person    5 or 6 6 or 7 10 12
Installation Area(sq. mt) 4 4.5 8 16
Water output temp. (° C) 85 ± 5 °C under normal Sunny conditions
FPC capillary tube Model:        
No. fins 9 9 18 36
Collector Material Copper
Collector Box        
Coating Extruded Aluminum Powder Coated
Collector Size 2050 mm x 1050 mm x100 mm
Insulation 48 Kg/Cu,metre density Rock wool slab for standard model
box back sheet Aluminum sheet
Solar Collector Absorber        
Coating Selective black chrome – Nalsun
Insulation cover material Aluminum sheet
Bonding between fin        
And riser Metallurgical bonding
Header 99.9 %   copper  1”   , 22 SWG
Riser 99.9 %   copper  ½ “   24 SWG
Hot Water Tank        
Tank type Cylindrical – horizontal
Tank material (Inner) Stainless Steel SS 304 (Food Grade) - 0.9 mm
Insulating material for tank 48 Kg/Cu,metre density Rock wool slab for standard model
Electric Heater (optional) No need -     if need 2KVS 
 Pressure pump model is available   *Specifications are subject to change without prior notice".

 

 

MG ETC SOLAR WATER HEATER TECHNICALSPECIFICATION

 

MG Solar Water  Heater ETC Model 100 150 200 250
Usage No. of person 3 or 4 5 or 6 8 10
Installation Area(sq. mt) 2.1 3.1 3.8 4.7
Water output temp. (° C) 40 ± 5 °C Under Normal Sunny Conditions
ETC tube Model: No. of Tubes 14 20 28 34
Material Glass 3.3
Coating Selective Absorptive Coating
Glass Sealing Silicon Rubber
Hot Water Tank material (Inner) Stainless Steel SS 304 (Food Grade) - 0.5 mm

APPLICATIONS:
In Restaurants Clubs & Resorts In Hospitals Hostels Institutions In Canteens and Laundries For Swimming pool water heating In most Process Industries In Green buildings to earn renewable energy points As In feed hot water to Boilers For Can washing at Dairy collection centers General washing & cleaning purposes In Agricultural sector.

INSTALLATION GUIDELINES
1. Unobstructed sunlight (Shadow free area)
2. Flat (Preferable) or sloping roof area as requested
3. Area should be near to point of usage (bathroom / kitchen) : to
    avoid long hot water piping and heat losses
4. The system (solar Evacuated tube collectors) should face south
    direction
5. Fresh (cold) water tank at a height @ 5-7 ft above the system
    tank height
6. 5 years guarantee, onsite after sales service
 